Note A: For each reduction of 0.01 percentage point below the specified
maximum for carbon, an increase of 0.06 percentage point above the
specified maximum for manganese is permitted, up to a maximum of
1.50 % by heat analysis and 1.60 % by product analysis.Note B: If copper-containing steel is specified in the purchase
order.
Mechanical Properties
Structural Tubing
Tensile Strength, min, ksi [MPa]
Yield Strength, min, ksi [MPa]
Elongation in 2 in. min, %
Note B: Applies to specified wall thicknesses (t ) equal to or greater than
0.180 in. [4.57 mm]. For lighter specified wall thicknesses, the
minimum elongation values shall be calculated by the formula:
percent elongation in 2 in. [50 mm] = 61t + 12, rounded to the
nearest percent. For A500M use the following formula: 2.4t + 12,
rounded to the nearest percent.